Diagnostic kits
database

Arabis Mosaic Virus + Grapevines Fan Leaf Virus (ArMV + GFLV)

DAS-ELISA

Organism/pest:
Arabis Mosaic Virus + Grapevines Fan Leaf Virus (ArMV + GFLV)
Taxonomic group:

Virus

Manufacturer:
Sediag
Sediag
Arabis Mosaic Virus + Grapevines Fan Leaf Virus (ArMV + GFLV)
Type of detection:
Serological
Type of test:
ELISA test
Type of method:
DAS-ELISA
Description of the test:
ELISA diagnostic kit for ArMV + GFLV
Type of sample:
Grapevine
Number of target:
2
Target:
ArMV + GFLV
Available extraction method:
Grind 1g of plant material in 10mL of grapevine extraction buffer
Available extraction method PDF:
-
Scope:
Detection of CN in plant material.
EPDIA validation datasheet:
Other validation data:
SEDIAG Certificat of perfomance
Other Validation data PDF:
References:
Walter B. 1997. « Control of the fanleaf virus disease of the grapevine : present and future». 5th Regio Meeting, Basel, CH, 20 nov.  
Walter B., 1997. Sanitary selection of the grapevine : Protocols for the detection of viruses and virus-like diseases. Les Colloques INRA Editions, 86, 225 .  
Walter B. 1994. « Le court-noué de la vigne » Avantages et limite de la détection par ELISA. Le Progrès Agric.Vitic. 11, 320-328.  
Van Regenmortel MHV, Dubs M-C, 1993. Serological procedures. In : Matthews REF, ed. Diagnosis of Plant Virus Diseases. London, UK : 159-214.  
Catalano L. et al., 1990. ELISA for the detection of grapevine fanleaf nepovirus in Xiphinema index., Proc. 10th Meeting ICVG. Volos, Greece, 1991, 243-246.  
Lazar J. et al., 1990. Detection of some nepoviruses (GFV, GFV-YM, GCMV, ArMV) in the seeds and seedlings of grapevines by ELISA., Kertgazdasag, 22 (4), 58-72.  
Huss, B. et al., 1986. Diagnostic des virus du COURT-NOUE de la vigne et étude d’interactions entre isolats : Utilisation d’anticorps Monoclonaux. PhD  24 novembre 1986. Laboratory of M.H.V. Van Regenmortel.  
Walter B. et al., 1984. ELISA Détection sérologique des virus du Court-noué de la vigne par le test ELISA., Agronomie, 4, 527-534.  
Bouquet A., 1983. Détection immunoenzymatique du virus du court-noué de la vigne dans son vecteur Xiphinema index Thorne et Allen., Comptes rendus des séances de l’Académie des Sciences, Paris, S.III, 296, 271-273.  
Van Regenmortel M. 1982. Serology and Immunochemistry of Plant Viruses., Academic Press, 302.  
M.H.V . Van Regenmortel et al. Grapevine Fanleaf virus detection in various grapevine organs using polyclonal and monoclonal antibodies. Vitis, 25 178-188.
References PDF:
-
Website:
Contact:
Country of production:

France

Product code:
FLAr-LNC
FLAr-LPC
FLAr-SRA 0500
FLAr-SRA 1000
FLAr-SRA 5000
FLAr-XRA 0500
FLAr-XRA 1000
FLAr-TRA 0500
Available kit format:
500, 1000 or 5000 tests
Components:
Reagent Set (SRA) : Antibodies (Coating and Conjugate)
Full Kit (XRA) : Antibodies (Coating and Conjugate), Positive control, Negative control, Buffers (Coating, Conjugate, Substrat, Wash and Extraction), Substrate Tablets, ELISA plates.
Kit 480 (TRA) : Antibodies (Coating and Conjugate), Positive control, Negative control, Buffers 1X (Coating, Conjugate, Substrat), Substrate Tablets.
Other information:
-

Back to catalogue